Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Semin Thromb Hemost ; 50(2): 275-283, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37327884

RESUMEN

Platelets are central elements of hemostasis and also play a pivotal role in the pathogenesis of thrombosis in coronavirus disease 2019. This study was planned to investigate the effects of different severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) recombinant spike protein variants on platelet morphology and activation. Citrated whole blood collected from ostensibly healthy subjects was challenged with saline (control sample) and with 2 and 20 ng/mL final concentration of SARS-CoV-2 recombinant spike protein of Ancestral, Alpha, Delta, and Omicron variants. Platelet count was found to be decreased with all SARS-CoV-2 recombinant spike protein variants and concentrations tested, achieving the lowest values with 20 ng/mL Delta recombinant spike protein. The mean platelet volume increased in all samples irrespective of SARS-CoV-2 recombinant spike protein variants and concentrations tested, but especially using Delta and Alpha recombinant spike proteins. The values of both platelet function analyzer-200 collagen-adenosine diphosphate and collagen-epinephrine increased in all samples irrespective of SARS-CoV-2 recombinant spike protein variants and concentrations tested, and thus reflecting platelet exhaustion, and displaying again higher increases with Delta and Alpha recombinant spike proteins. Most samples where SARS-CoV-2 recombinant spike proteins were added were flagged as containing platelet clumps. Morphological analysis revealed the presence of a considerable number of activated platelets, platelet clumps, platelet-monocyte, and platelet-neutrophils aggregates, especially in samples spiked with Alpha and Delta recombinant spike proteins at 20 ng/mL. These results provide support to the evidence that SARS-CoV-2 is capable of activating platelets through its spike protein, though such effect varies depending on different spike protein variants.


Asunto(s)
COVID-19 , Glicoproteína de la Espiga del Coronavirus , Humanos , SARS-CoV-2 , Colágeno
2.
Diagnosis (Berl) ; 11(1): 91-96, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37665244

RESUMEN

OBJECTIVES: There is limited information on the influence of collecting small amounts of blood on the quality of blood gas analysis. Therefore, the purpose of this study was to investigate the effects of different degrees of underfilling of syringes on test results of venous blood gas analysis. METHODS: Venous blood was collected by venipuncture from 19 healthcare workers in three 1.0 mL syringes for blood gas analysis, by manually aspirating different volumes of blood (i.e., 1.0, 0.5 and 0.25 mL). Routine blood gas analysis was then immediately performed with GEM Premier 5,000. The results of the two underfilled syringes were compared with those of the reference syringe filled with appropriate blood volume. RESULTS: The values of most assayed parameters did not differ significantly in the two underfilled syringes. Statistically significant variations were found for lactate, hematocrit and total hemoglobin, the values of which gradually increased as the fill volume diminished, as well as for sodium concentration, which decreased in both insufficiently filled blood gas syringes. The bias was clinically meaningful for lactate in syringe filled with 0.25 mL of blood, and for hematocrit, total hemoglobin and sodium in both syringes containing 0.5 and 0.25 mL of blood. CONCLUSIONS: Collection of smaller volumes of venous blood than the specified filling volume in blood gas syringes may have an effect on the quality of some test results, namely lactate, hematocrit, total hemoglobin and sodium. Specific indications must be given for standardizing the volume of blood to be collected within these syringes.


Asunto(s)
Ácido Láctico , Jeringas , Humanos , Análisis de los Gases de la Sangre/métodos , Sodio , Hemoglobinas
3.
Int J Mol Sci ; 24(11)2023 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-37298324

RESUMEN

This study investigated the biological effects on circulating monocytes after challenge with SARS-CoV-2 recombinant spike protein. Whole blood collected from seven ostensibly healthy healthcare workers was incubated for 15 min with 2 and 20 ng/mL final concentration of recombinant spike protein of Ancestral, Alpha, Delta, and Omicron variants. Samples were analyzed with Sysmex XN and DI-60 analyzers. Cellular complexity (i.e., the presence of granules, vacuoles and other cytoplasmic inclusions) increased in all samples challenged with the recombinant spike protein of the Ancestral, Alpha, and Delta variants, but not in those containing Omicron. The cellular content of nucleic acids was constantly decreased in most samples, achieving statistical significance in those containing 20 ng/mL of Alpha and Delta recombinant spike proteins. The heterogeneity of monocyte volumes significantly increased in all samples, achieving statistical significance in those containing 20 ng/mL of recombinant spike protein of the Ancestral, Alpha and Delta variants. The monocyte morphological abnormalities after spike protein challenge included dysmorphia, granulation, intense vacuolization, platelet phagocytosis, development of aberrant nuclei, and cytoplasmic extrusions. The SARS-CoV-2 spike protein triggers important monocyte morphological abnormalities, more evident in cells challenged with recombinant spike protein of the more clinically severe Alpha and Delta variants.


Asunto(s)
COVID-19 , Monocitos , Humanos , Glicoproteína de la Espiga del Coronavirus/genética , SARS-CoV-2
4.
Nanoscale Adv ; 1(11): 4433-4441, 2019 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-36134421

RESUMEN

In this work we show that the incidence angle of group-III element fluxes plays a significant role in the diffusion-controlled growth of III-V nanowires (NWs) by molecular beam epitaxy (MBE). We present a thorough experimental study on the self-assisted growth of GaAs NWs by using a MBE reactor equipped with two Ga cells located at different incidence angles with respect to the surface normal of the substrate, so as to ascertain the impact of such a parameter on the NW growth kinetics. The as-obtained results show a dramatic influence of the Ga flux incidence angle on the NW length and diameter, as well as on the shape and size of the Ga droplets acting as catalysts. In order to interpret the results we developed a semi-empirical analytical model inspired by those already developed for MBE-grown Au-catalyzed GaAs NWs. Numerical simulations performed with the model allow us to reproduce thoroughly the experimental results (in terms of NW length and diameter and of droplet size and wetting angle), putting in evidence that under formally the same experimental conditions the incidence angle of the Ga flux is a key parameter which can drastically affect the growth kinetics of the NWs grown by MBE.

5.
Nanoscale ; 10(43): 20207-20217, 2018 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-30357204

RESUMEN

One obstacle for the development of nanowire (NW) solar cells is the challenge to assess and control their nanoscale electrical properties. In this work a top-cell made of p-n GaAs core/shell NWs grown on a Si(111) substrate by Molecular Beam Epitaxy (MBE) is investigated by high resolution charge collection microscopy. Electron Beam Induced Current (EBIC) analyses of single NWs have validated the formation of a homogeneous radial p-n junction over the entire length of the NWs. The radial geometry leads to an increase of the junction area by 38 times with respect to the NW footprint. The interface between the NWs and the Si(111) substrate does not show any electrical loss, which would have led to a decrease of the EBIC signal. Single NW I-V characteristics present a diodic behavior. A model of the radial junction single NW is proposed and the electrical parameters are estimated by numerical fitting of the I-Vs and of the EBIC map. Solar cells based on NW arrays were fabricated and analyzed by EBIC microscopy, which evidenced the presence of a Schottky barrier at the NW/ITO top contact. Improvement of the top contact quality is achieved by thermal annealing at 400 °C, which strongly reduces the parasitic Schottky barrier.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...